Introduction
The solenoid coil is the key component of a hydraulic valve. Sometimes, the solenoid valve can be broken due to various reasons. This article will analyze all the possible reasons and how to tackle with them.
Tools
- 
                  
                  - 
            Test the solenoid with a multi-meter, if the resistance is close to zero or infinity, it means that solenoid is either open circuit or broken circuit. 
- 
            If open circuit or broken circuit happens, you need to change a new solenoid coil. 
 
- 
            
- 
                  
                  - 
            If there is a plug on the solenoid valve, you may need to check the metal spring clip inside the socket. 
- 
            If this problem happens, modify the wire connection, repair or replace the plug or socket. 
 
- 
            
- 
                  
                  - 
            The valve element can be problematic because of too much water in the compressed air or too many foreign particles in the liquid medium. 
- 
            Check the valve element and get rid of all the foreign matters. 
- 
            If problem still occurs, replace the full valve element. 
 
- 
            
- 
                  
                  - 
            bad wiring. Re-connect the wire. 
- 
            Regulate voltage to the normal range. 
- 
            weld the solenoid coil again. 
- 
            regulate the pressure differences. 
 
- 
            
- 
                  
                  - 
            replace the sealing parts of broken valve element 
- 
            replace the solenoid valve with a suitable one for medium with a higher temperature. 
- 
            clean the foreign matters in the valve element. 
 
- 
            
To reassemble your device, follow these instructions in reverse order.